Building a safe and secure embedded world

MODBUS TCP SERVER to PROFIBUS PA Master Gateway (mbGate PA)

Simple connection of Profibus PA Slave devices to Modbus control systems via internal I/O mapping

  • mbGate PA re-uses power conditioners in technology upgrade projects
  • No PROFIBUS DP Intermediate Segment required
  • Prepared for Integration in Standard Engineering and Plant Asset Management Tools

Key Component for Transition to State-of-the-Art Technology

  • Simple replacement of installed PROFIBUS DP/PA segment couplers
  • Re-use of existing PROFIBUS PA segments without requiring modification

Direct Connectivity to PROFIBUS Segments

  • Acting as Modbus Server and PROFIBUS PA Master
  • Connects up to 4 PROFIBUS PA Segments to Modbus TCP

Configuration, Parameterization and Plant Asset Management Using Standard Industry Tools

  • Supports major Modbus engineering tools such as Schneider Unity Pro or Siemens TIA Portal
  • Included CommDTM allowing use in FDT/DTM frame applications
  • EDD-based device parametrization using Siemens Simatic PDM
HardwareProcessor
Status LEDs (Gateway)

Status LEDs (Fieldbus)
Altera Cyclone V SoC with dual-core ARM Cortex-A9
PWR (power supply), RUN (operation), ERR (error), CFG (configuration and update)
SF (system fault), BF (bus fault)
Interfaces and ConnectorsEthernet




PROFIBUS PA
2 * IEEE 802.3 100BASE-TX / 10BASE-T, managed Ethernet switch for daisy chain totpology
Connectors: RJ45
Protocol: Modbus TCP Server
RESTful API interface for device configuration 
Up to 4 PROFIBUS PA (MBP) segments (refer to the section „Order Numbers“), 
Bus-powered Medium Attachment Unit (MAU): Fieldbus voltage range: 9 VDC ... 32 VDC, 
current consumption 10 mA, 
Connectors: 3-position screw connection, galvanically isolated
Physical PropertiesDimensions (H x W x D)
Weight
Power Supply



Operating / Storage Temperature
Relative Humidity
Cooling
Coating
Mounting
Protection Class
100 mm x 35 mm x 115 mm
Approx. 0.25 kg
18 VDC ... 32 VDC; SELV/PELV power supply mandatory
Typical input current: 200 mA, maximum input current: 1 A (allowing for in-rush current at switch-on)
No power supply to PROFIBUS PA segments through mbGate PA
-40 °C ... +70 °C / -40 °C ... +85 °C (see detailed mounting description in user manual)
10 % ... 95 %, non-condensing
Convection, no fan
Conformal coating based on ANSI / ISA-S71.04 G3
DIN rail 35 mm
IP20